        Management of dislocated IOL  
             
        Kim WS 
           
        Pusan (Südkorea) 
         
          Decenteration and dislocation of a posterior chamber IOL can occur 
          after complicated cataract surgery. The causes are loss of capsular or 
          zonular integrity during surgery or asymmetric placement of haptics. 
          There are few reports of this complication in the literature, 
          partly because sufficient time is necessary for its clinical manifestation. 
          The purpose of this presentation is to review the literature 
          regarding the risk factors for bag dislocation, discuss methods to 
        prevent it, and present treatment technique. 